FDOT Standard Plans Index 425-040: Gutter Inlet Type S

Short answer

Index 425-040 is the FDOT Standard Plan for Gutter Inlet Type S, part of Series 425 (Structures). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.

Design Criteria

Design Criteria and Guidance FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG)

Design Assumptions and Limitations

Design Assumptions and Limitations Type S inlets are intended for use in shoulder gutter on facilities subject to heavy wheel loads (H-20). Type V Inlets are intended for use in valley gutter. This inlet is suitable for village swales, ditches, or other areas subject to heavy wheel loads and minimum debris.

This inlet may be placed in areas subject to occasional pedestrian traffic such as landscaped areas and pavement areas where pedestrians can walk around the inlet. This inlet is not for use in a bicycle way.

Payment

Payment Item number Item Description Unit Measure 425-70B Gutter Type S EA 425-71B Gutter Type V EA Gutter Transitions are paid for under the Gutter pay item. See the BOE and Specification 425 for additional information on payment, pay item use and compensation. RECOMMENDED MAXIMUM PIPE SIZES Inlet Inside Width Pipe Size 2'-11" or 3'-3 24" 3'-10" or 4'-0" 30" Note: Recommended sizes are based on concrete pipe.

Sizes for other types of pipe must be verified for fit in accordance with Index 425-001 . For larger pipe use J-Bottom, See Index 425-010 .

What your plans must show

Plan Content Requirements for this index — the SPI's checklist for designers.

  • Include Drainage Structure information in the Plans in accordance with the requirements of the Basis of Estimates Manual ( BOE ) and the FDM. Require the reticuline grate option for Type S inlets in locations where bicycle traffic is anticipated. Specify Alt. G grates when galvanized grates are required.
gutterprecastinletbarsctrsrevisiontransitionwallgratetabledetailsslab

How PDFDepth uses this index

When a plan set cites Index 425-040, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.

Related indexes in Series 425

All FDOT Standard Plans indexes

Try it yourself — open your plan set in PDFDepth

Review, measure, and check plan sets against the standards they cite — free for 14 days.

Start for Free

Text extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.