FDOT Standard Plans · FY 2026-27 · Series 425: Structures
FDOT Standard Plans Index 425-053: Ditch Bottom Inlet Types F and G
Short answer
Index 425-053 is the FDOT Standard Plan for Ditch Bottom Inlet Types F and G, part of Series 425 (Structures). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.
Design Criteria
Design Criteria and Guidance FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG)
Design Assumptions and Limitations
Design Assumptions and Limitations These inlets are designed for use in ditches, medians, pavement areas, or other areas subject to heavy traffic loading, minimal debris, and bicycle traffic. These inlets may be placed in areas subject to occasional pedestrian traffic such as landscaped areas and pavement areas where pedestrians can walk around the inlet. When inlet is placed in areas subject to bicycle traffic, install filler bar when clearance or gap is greater than 5/8” as shown in Index 425-031 .
Recommended maximum pipe sizes for concrete pipe: For 2’6” Inlet Inside Width (Type F): 18” For 4’0” Inlet Inside Width (Type F): 30” For 4’10”/ 5’0” Inlet Inside Width (Type G): 42” Sizes for other types of pipe must be checked for fit in accordance with Index 425-001 . For larger pipe see bottom detail in Index 425-010 .
Payment
Payment Item number Item Description Unit Measure 425-156- Inlets, Ditch Bot, Type F EA 425-157- Inlets, Ditch Bot, Type G EA See the BOE and Specification 425 for additional information on payment, pay item use and compensation.
What your plans must show
Plan Content Requirements for this index — the SPI's checklist for designers.
- Include Drainage Structure information in the Plans in accordance with the requirements of the Basis of Estimates Manual ( BOE ) and the FDM.
How PDFDepth uses this index
When a plan set cites Index 425-053, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.
Related indexes in Series 425
- Index 425-001 — Manhole Covers, Frames, Tops, and Supplementary Inlet Details
- Index 425-010 — Structure Bottoms Type J and P
- Index 425-020 — Curb Inlets Types 1-10
- Index 425-021 — Curb Inlet Top Types 5 and 6
- Index 425-022 — Curb Inlet Type 7
- Index 425-023 — Curb Inlet Type 8
- Index 425-024 — Curb Inlet Type 9
- Index 425-025 — Curb Inlet Type 10
Try it yourself — open your plan set in PDFDepth
Review, measure, and check plan sets against the standards they cite — free for 14 days.
Start for FreeText extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.