Skip to content

FDOT Standard Plans · FY 2026-27 · Series 425: Structures

FDOT Standard Plans Index 425-090: Safety Modification for Inlets in Box Culverts

Short answer

Index 425-090 is the FDOT Standard Plan for Safety Modification for Inlets in Box Culverts, part of Series 425 (Structures). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.

Design Criteria

Design Criteria and Guidance FDOT Design Manual (FDM) ; Drainage Manual (DM) ; Drainage Design Guide (DDG)

Design Assumptions and Limitations

Design Assumptions and Limitations Use this Index to modify Box Culvert Inlets for Safety.

Payment

Payment Item number Item Description Unit Measure XXX-XXX-XXX Project Specific Unit See the BOE and Specification 425 and 400 for additional information on payment, pay item use and compensation.

What your plans must show

Plan Content Requirements for this index — the SPI's checklist for designers.

  • Include Drainage Structure information in the Plans in accordance with the requirements of the Basis of Estimates Manual ( BOE ) and the FDM.
variesconcreteditchpavementwallstructuresrevisionslotslopelessthandescription

How PDFDepth uses this index

When a plan set cites Index 425-090, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.

Related indexes in Series 425

All FDOT Standard Plans indexes

Try it yourself — open your plan set in PDFDepth

Review, measure, and check plan sets against the standards they cite — free for 14 days.

Start for Free

Text extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.