FDOT Standard Plans · FY 2026-27 · Series 450: Structures
FDOT Standard Plans Index 450-299: Florida - U Beams Build - Up & Deflection Data
Short answer
Index 450-299 is the FDOT Standard Plan for Florida - U Beams Build - Up & Deflection Data, part of Series 450 (Structures). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.
Design Criteria
Design Criteria AASHTO LRFD Bridge Design Specifications ; Structures Detailing Manual ( SDM ) ; Structures Design Guidelines ( SDG )
Design Assumptions and Limitations
Design Assumptions and Limitations Use this stan dard in conjunction with Indexes 45 0 - 210, 45 0 - 248, 45 0 - 254, 45 0 - 263 and 45 0 - 272. Unless otherwise required as a design parameter, beam camber for computing the theoretical build - up must be based on 120 - day old beam concrete. Consider the effects of horizontal curvature with bridge deck cross slope when determining the minimum theoretical build - up over the tip of the inside flange.
Consider that the vertical curve geometry is along the effective alignment along a chord at the c enterline of the beam, which may be different from the alignment parallel to the Profile Grade Line. For a given size and type of beam, beam camber and associated Dim B and Dim D will vary due to span lengths and beam spacings. Dim B and Dim D will also vary from span to span along the length of a bridge due to deck geometry.
To provide for better aesthet ics and potentially easier detailing of the supporting pedestals, where possible adjust the values of Dim B and Dim D over equal height beams in adjacent spans so as to allow the beam bottom flanges to line up. Dim B and Dim D do not necessarily have to be the same value for a single beam. See the following sketch : Standard Plan s Instructions Topic No.
625 - 010 - 003 Index 450 - 299 Florida - U Beams Build - Up & Deflection Data
Payment
Payment Include estimated build - up concrete quantities with the estimated deck concrete quantities. Do not break out estimated build - up concrete quantities. In the absence of more refined calculations, the following method to calculate estimated concrete build - up quantities may be used: For Case 1, 2 & 3 V = Left Flange + Right Flange: V = LW [ C+ ( B + D - 2C 6 ) ] 27 + LW [ C+ ( B+D - 2C 6 ) ] 27 For Case 4 V = Left Flange + Right Flange: V = LW [ ( B+D 2 ) + ( 2 3 ( C - B+D 2 ) ) ] 27 + LW [ ( B+D 2 ) + ( 2 3 ( C - B+D 2 ) ) ] 27 Where: V = Total Volume of build - up per beam (CY) L = Beam Length (ft) W = Width of beam top flange (ft) B; C; D = Build - up Thickness (ft)
What your plans must show
Plan Content Requirements for this index — the SPI's checklist for designers.
- Complete the following "Build
- - Up and Deflection Data Table for Florida
- - U Beams" and include it on the superstructure detail sheets. See FDM 115 for more information regarding use of Data Tables.
How PDFDepth uses this index
When a plan set cites Index 450-299, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.
Related indexes in Series 450
- Index 450-010 — Series Prestressed Florida - I Beams
- Index 450-036 — Index 450-036
- Index 450-045 — Index 450-045
- Index 450-054 — Index 450-054
- Index 450-063 — Index 450-063
- Index 450-072 — Index 450-072
- Index 450-078 — Index 450-078
- Index 450-084 — Index 450-084