FDOT Standard Plans · FY 2026-27 · Series 521: Incidental Construction
FDOT Standard Plans Index 521-513: Concrete Barrier /Noise Wall T-Shaped Spread Footing
Short answer
Index 521-513 is the FDOT Standard Plan for Concrete Barrier /Noise Wall T-Shaped Spread Footing, part of Series 521 (Incidental Construction). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.
Design Criteria
Design Criteria See Instructions for Index 521-510 and/or Index 521-511.
Design Assumptions and Limitations
Design Assumptions and Limitations Use this Standard with Index 521-510 and/or 521-511 when the Concrete Barrier / Noise Wall (8'-0") and/or (14'-0") is installed on a T-Shaped spread footing. Footing stem wall may be widened at no additional cost, to accommodate slip forming. Project specific details are required for the use of 10'-0" and 12'-0" tall Concrete Barrier / Noise Walls.
Base these details on Indexes 521-510 and 521-511.
Payment
Payment Item number Item Description Unit Measure 521-72-24 Shoulder Concrete Barrier/Noise Wall, 8'-0” LF 521-72-25 Shoulder Concrete Barrier /Noise Wall, 10'-0” LF 521-72-26 Shoulder Concrete Barrier /Noise Wall, 12'-0” LF 521-72-27 Shoulder Concrete Barrier /Noise Wall 14'-0” LF
What your plans must show
Plan Content Requirements for this index — the SPI's checklist for designers.
- See Instructions for Index 521-510 and/or Index 521-511. Include project specific details for 10'-0" and 12'-0" tall Concrete Barrier / Noise Walls.
How PDFDepth uses this index
When a plan set cites Index 521-513, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.
Related indexes in Series 521
- Index 521-001 — Concrete Barrier
- Index 521-002 — Pier Protection Barrier
- Index 521-005 — Concrete Barrier at Toll Sites
- Index 521-010 — Opaque Visual Barrier (OVB)
- Index 521-404 — Guardrail Transitions - Existing Post & Beam Bridge Railings (Narrow & Recessed Curbs)
- Index 521-405 — Guardrail Transitions - Existing Post & Beam Bridge Railings (Wide Curbs)
- Index 521-422 — Traffic Railing (42" Vertical Shape)
- Index 521-423 — Traffic Railing (32" Vertical Shape)
Try it yourself — open your plan set in PDFDepth