FDOT Standard Plans Index 534-250: Perimeter Wall

Short answer

Index 534-250 is the FDOT Standard Plan for Perimeter Wall, part of Series 534 (Incidental Construction). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.

Design Criteria

Design Criteria AASHTO LRFD Bridge Design Specifications ; Structures Design Guidelines ( SDG )

Design Assumptions and Limitations

Design Assumptions and Limitations Design Assumptions: Wall heights are a nominal 8 feet above finished grade. Foundations have been designed for loose sand with an uncorrected SPT blow count of N=5 or greater. Clayey soils were investigated and did not control the design.

Precast Option Design Assumptions: • Wall Panels, as designed, are adequate for all wind zones when installed between posts spaced at 20'-0". • Post reinforcing and foundation depths are based on 20'-0" post spacing with a maximum wind exposed wall height of 9'-0". • Auger cast pile foundations were designed in accordance with the Soils and Foundations Handbook , Appendix B.

Masonry Option Design Assumptions: • Walls are designed as a continuous cantilevered wall in accordance with ACI 530 using Strength Design for a maximum wind exposed wall height of 8'-8" with the top of foundation a minimum of 6" below grade. • Foundations are designed in accordance with AASHTO LRFD , Section 15. Design Limitations: See the FDM , 264 for limitations on the applicability of this Index.

Perimeter Walls are not designed for vehicle impact loads. If the walls cannot be placed at the required set back distances or behind traffic railings or guardrail they will not be allowed. Ensure system is constructible with consideration of overhead clearances (i.e.

overhead services, tree canopies, existing overhead structures, etc.) and existing underground services along the entire length of the wall. • If foundations will be installed on a slope, adjust the standard foundation depths based on the Soils and Foundations Handbook .

Payment

Payment Item number Item Description Unit Measure 534-73 Perimeter Wall SF 563-A Anti-Graffiti Coating SF Example PERIMETER WALLS DATA TABLE 'Table Date 01-31-14 WALL ) NO . (I STATION TO STATION FRONT FACE TEXTURE (2) PRECAST POST CAP (TYPE) LIMITS OF ANTI -GRAFFITI COATING (2) FRONT FACE/ BACK FACE/ BOTH AREA (SQUARE FT) (SEE NOTE 4) 1 125+25.40 to 126+30.40 Split Face Type 2 Front Face 840 I 126+30.40 to 126+50.40 Split Face Type 2 Both 320 2 126+75.22 to 127+90.00 Split Face 8 Fluted Type 2 None 0 2 127+90.00 to 128+50.00 Split Face 8 Fluted Type 2 Both 960 1) See wall control drawings. (2) Specify texture and limits of anti -graffiti coatings in the Table.

GENERAL NOTES [Notes Date 01-31-14]: 1. Wind Speed is 130 MPH. 2.

Colors shall be per Federal color Chart, Federal Standard No 595C. Wall Color #31136, Post/Pilaster Color #23722, Caps Color #23722. 3.Coat wall for stations shown in table with sacrificial anti -graffiti coating.

4. Height for Class 5 finish and/or anti -graffiti coating is from finished grade to top of wall (8 feet). 5.

Work these Data Tables with Index 534-250. 6. Front Face indicates roadway side of wall.

Back Face indicates non -roadway side of wall. Index 534-250 Perimeter Wall

What your plans must show

Plan Content Requirements for this index — the SPI's checklist for designers.

  • • Perimeter Wall Alignment / Location
  • • Begin/End Wall Stationing and Offsets
  • • Offset definition; usually from Baseline to Front Face of Wall
  • • Adjacent overhead or in-ground services
  • • Limits of sod or seeding/topsoil application
  • • Where removal of or improvements to organic soils are necessary, show the limits of organic soils and the limits of required improvements in the plans along with removal/improvement methods and method of payment. Elevation
  • • Bottom of Wall Elevations and Finished Grade Line.
  • • Step Locations If the base elevations or wall height requirements change along the length of the project, step bottom and/or top of walls and post/pilaster elevations to maintain the aesthetic qualities while meeting the design criteria requirements. o Drainage Holes (Including type) Index 534-250 Perimeter Wall o Adjacent overhead or in-ground services o Limits of anti-graffiti coating (if required) o Guardrail or delineators on back face of wall Complete the "PERIMETER WALLS DATA TABLE" with notes; include them in the plans. See FDM 115 for more information regarding use of Data Tables.
wallpanelspostpanelheightcastgroutpostsspecificationbetweenminimumwalls

How PDFDepth uses this index

When a plan set cites Index 534-250, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.

Related indexes in Series 534

All FDOT Standard Plans indexes

Try it yourself — open your plan set in PDFDepth

Review, measure, and check plan sets against the standards they cite — free for 14 days.

Start for Free

Text extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.