FDOT Standard Plans · FY 2026-27 · Series 400: Structures
FDOT Standard Plans Index 400-021: Concrete Steps
Short answer
Index 400-021 is the FDOT Standard Plan for Concrete Steps, part of Series 400 (Structures). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.
Design Criteria
Design Criteria Florida Building Commission " Florida Building Code ", 2004 Edition
Design Assumptions and Limitations
Design Assumptions and Limitations Do not use Index 400-021 for suspended (structural) steps or stairways. Maximum of 12 risers permitted between level landing areas. Use of Indexes 515-052 , 515-062 , 515-070 , 515-080 or project specific pedestrian railings is required.
Payment
Payment Item number Item Description Unit Measure 400-0-13 Concrete Class NS, Concrete Steps CY 415-1-6 Reinforcing Steel - Miscellaneous LB See the BOE and Specifications 400 & 415 for additional information on payment, pay item use and compensation.
What your plans must show
Plan Content Requirements for this index — the SPI's checklist for designers.
- Summary Boxes: Steps should be shown on the “ Summary General Items” or the appropriate tabulation sheet for landscaping or architecture. Plans: Show locations and lengths of steps in the Plans. Consider maximum number of risers between landings, landing widths and tie-ins to adjacent sidewalks when establishing overall limits of steps. Coordinate profile of steps and landings with shapes of supporting embankments. Show Index 515-052 , 515-062 , 515-070 , 515-080 or project specific pedestrian railings. Label steps by name or Index number.
How PDFDepth uses this index
When a plan set cites Index 400-021, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.
Related indexes in Series 400
- Index 400-010 — Cantilever Retaining Wall (C - I - P)
- Index 400-011 — Gravity Wall
- Index 400-090 — Approach Slabs (Flexible Pavement Approaches)
- Index 400-091 — Approach Slabs ( Rigid Pavement Approaches)
- Index 400-289 — Concrete Box Culvert Details
- Index 400-291 — Precast Concrete Box Culvert Supplemental Details
- Index 400-292 — Standard Precast Concrete Box Culverts
- Index 400-510 — Composite Elastomeric Bearing Pads - Prestressed Florida - I and AASHTO Type II Beams