FDOT Standard Plans Index 515-051: Bridge Pedestrian/Bicycle Railing (Steel)

Short answer

Index 515-051 is the FDOT Standard Plan for Bridge Pedestrian/Bicycle Railing (Steel), part of Series 515 (Incidental Construction). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.

Design Criteria

Design Criteria See Standard Plan s Instructions Index 515 - 0 52.

Design Assumptions and Limitations

Design Assumptions and Limitations Bridge Pedestrian/Bicycle Railing is limited to use on bridges with expansion joint thermal movements not exceeding 5". Scheme 3 is limited to bridge retrofit applications where additional sidewalk width is required. See Standard Plan s Instructions Index 515 - 0 52 for additional information.

Payment

Payment Item number Item Description Unit Measure 515 - 2 - 1BB Pedestrian / Bicycle Railing, Non Specified, 42" (Type__) LF 515 - 2 - 1BB Pedestrian / Bicycle Railing, Non Specified, 48" (Type__) LF 515 - 2 - 2BB Pedestrian / Bicycle Railing, Steel Only, 42" (Type__) LF 515 - 2 - 2BB Pedestrian / Bicycle Railing, Steel Only, 48" (Type__) LF Include concrete and reinforcing steel quantities for the concrete curb (Scheme 2) in the bridge deck plan quantity pay items.

What your plans must show

Plan Content Requirements for this index — the SPI's checklist for designers.

  • In the Structures and/or Roadway Plans: Provide railing layout Control Drawings to show post spacing, curb joint, V
  • - groove, deck joint, expansion joint locations and Scheme number. Label railing by name or Index number. For existing bridge retrofits special end treatment details may be required for perpendicular or flared wingwalls at Begin and End Bridge. Provide existing railing removal details when required. When either Index 515
  • - 0 61 are acceptable, include cross references to both indexes and use Pay Item 515
deckjointbridgepostconcreterailingcurbsteelopenjointsschemerail

How PDFDepth uses this index

When a plan set cites Index 515-051, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.

Related indexes in Series 515

All FDOT Standard Plans indexes

Try it yourself — open your plan set in PDFDepth

Review, measure, and check plan sets against the standards they cite — free for 14 days.

Start for Free

Text extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.