FDOT Standard Plans · FY 2026-27 · Series 515: Incidental Construction
FDOT Standard Plans Index 515-052: Pedestrian/Bicycle Railing (Steel)
Short answer
Index 515-052 is the FDOT Standard Plan for Pedestrian/Bicycle Railing (Steel), part of Series 515 (Incidental Construction). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.
Design Criteria
Design Criteria Structures Design Guidelines ( SDG 6.8); FDOT Design Manual ( FDM )
Design Assumptions and Limitations
Design Assumptions and Limitations This railing is not applicable for shielding drop-off hazards for motor vehicle traffic. This railing is applicable for cases where a pedestrian or bicyclist drop-off hazard exceeds 5'-0" or when a drop-off hazard is less than 5'-0" and is required by design or permit stipulations. Refer to FDM 222, for the definition of pedestrian and bicyclist "drop-off hazards".
Indexes 515-052 and 515-062 are similar in form and function. Select which of these railings to use at a given site based on District preferences, aesthetic or finish color requirements, corrosion concerns, potential theft issues, fabrication issues, weight of railing and any other project specific requirements. In some cases, both of these railings are acceptable for use and it is left to the contractor to select by the use of Pay Item 515-2-1BB.
See Index 515-051 for special requirements and modifications for use on bridges. A handrail is required where there are 3 or more steps and on ramps with a grade steeper than 5% to conform to the requirements of the Americans with Disabilities Act (ADA). Expansion joints shall be spaced at a maximum 40'-0" (differs from Index 515-062).
Railing must be continuous across a minimum of two posts. For the railing anchorage to provide stability against overturning, the concrete foundation (sidewalk, retaining wall, curb, etc.) must meet or exceed the requirements in this Standard. The following definitions apply to the use of this Standard; including Custom Infill Panels: 4" Sphere Rule - Clear openings of the railing below 42" height shall reject the passage of a 4" diameter sphere and clear openings above 42" height shall reject the passage of an 8" diameter sphere.
6" Sphere Rule - Clear openings of the railing below 27" height shall reject the passage of a 6" diameter sphere and clear openings above 27" height shall reject the passage of an 8" diameter sphere. Refer to the SDG for locations where the 4" Sphere rule is applicable. Providing adequate sight distance always takes priority over the 4" Sphere Rule.
Aesthetics play a crucial role in the determination of which railing infill type should be specified for a particular project. Alternate Infill Panel designs within the Standard Plan, include some that meet the 6" Sphere Rule and others that meet the 4" Sphere Rule. Index 515-052 Pedestrian/Bicycle Railing (Steel) Custom Infill Panels must be designed to meet the Design Criteria live load, and the applicable 4" or 6" Sphere Rule.
When designing Infill Panels, aesthetics is important; however, line of sight and safety issues must be a priority. Typically the clear space between the top and intermediate horizontal rails provides for adequate sight distances; however, for railing installations adjacent to sloped intersections, the infill area between the intermediate and bottom horizontal rails may still adversely affect the sight distance. Of the standard infill alternatives that meet the 4" Sphere Rule, the standard "Type 2 - Chain-Link" infill alternative creates the least obstruction to sight distance through the infill areas.
When a colored coating is desired and the additional cost is justified or reimbursed by the requesting local agency, then specify a coating in accordance with FDOT Standard Specifications for Road and Bridge Construction , Section 649-4. See FDM 127 for responsibilities of Local Maintaining Agencies for Community Aesthetic Features (CAF).
Payment
Payment Item number Item Description Unit Measure 515-2-1BB Pedestrian / Bicycle Railing, Non Specified, 42" (Type___) LF 515-2-1BB Pedestrian / Bicycle Railing, Non Specified, 48" (Type___) LF 515-2-2BB Pedestrian / Bicycle Railing, Steel Only, 42" (Type___) LF 515-2-2BB Pedestrian / Bicycle Railing, Steel Only, 48" (Type___) LF
What your plans must show
Plan Content Requirements for this index — the SPI's checklist for designers.
- In the Structures and/or Roadway Plans: Show Pedestrian Railings on sidewalks and walls as required. Designate locations where handrails are required. Label railing by name or Index number. When either Index 515-052 or 515-062 are acceptable, include cross references to both indexes and use Pay Item 515-2-1BB. When the 4" Sphere Rule must be met, modifications to the picket spacing (Type 1 & 3 Infill Panels) and intermediate railing height will be required in the Plans. Modify the Standard Plans in accordance with Method 1, Method 2 or Method 3 as defined in the Terms Of Use for the Borderless DGNs provided in the Standard Plans eBooklet. All Custom Infill Panels shall be fully detailed in the contract plans. A Custom Type Infill Panel Cell (00852-CTIP.cel) is available through the Structures CADD bar menu. Prepare project specific Infill Panel details when required using the Pedestrian/Bicycle Railing Custom Infill Panel CADD cell and include the cell(s) in the plans. Designate each individual project specific Infill Panel with a unique name for identification and cross reference purposes. Complete the following Data Tables and include them in the plans. See Introduction I.3 for more information regarding use of Data Tables. In the HEIGHT column of the Data Table, enter either "42" for standard Pedestrian/Bicycle Railing, "48" for Special Height Bicycle Railing, or required height where modified railing height is required. In the STYLE column of the Data Table, enter either "Type X" (where X = 1 thru 5 for the standard Infill Panel options) or "Custom" where custom Infill Panels are fully detailed in the plans. Index 515-052 Pedestrian/Bicycle Railing (Steel) " Max. Gap Varies 2'-0" (PBR) Panel Width (Typ.) x'-x" Height Infill Panel ƅ" (Typ.) (Typ.) " 8 1 " 4 3 " 4 3 " 2 1 1 (Typ.) Filler Strip " 2 1 "x 4 1 Infill Panel Ɓ" ℅ Panel Mullion SECTION A-A A A B B C C 2'-6" (SHBR) (Cut or Cast) Ɓ" ℅ Infill Panel Ɓ" ℅ Infill Panel See Detail "A" CUSTOM TYPE INFILL PANEL U-Channel ƂxƂxƃ = 48" Special Height Bicycle Railing SHBR = 42" Pedestrian/Bicycle Railing PBR Notes: STEEL PEDESTRIAN/BICYCLE RAILING CUSTOM TYPE INFILL PANEL DETAILS 2'-0" Sp. (18-8 SS) @ Head Screws #10xƅ" Pan Strip Ɓ"xƀ" Filler Ɓ" ℅ Infill Panel of Rail Inside Face (Top Shown, Bottom Similar) PANEL/RAIL CONNECTION DETAIL "A" U-Channel ƂxƂxƃ ON GRADES STEEPER THAN 5% PANEL ADJUSTMENT FOR RAILINGS xx" Stairs xx" Ramp to match grade trim top & bottom Lengthen panel and PANEL END CAP SECTION B-B (18-8 SS) @ 1'-0"± Sp. Pan Head Screws 3 ~ #10xƅ" Strip Ɓ"xƀ" Filler 4" Max. Gap Varies Panel Ɓ" ℅ Infill Post PANEL/SPLICE CONNECTION SECTION C-C 1'-0"± Sp. (18-8 SS) @ Head Screws 3 ~ #10xƅ" Pan Index 515-052 Pedestrian/Bicycle Railing (Steel)
How PDFDepth uses this index
When a plan set cites Index 515-052, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.
Related indexes in Series 515
- Index 515-021 — Pedestrian/Bicycle Bullet Railing for Traffic Railing s
- Index 515-022 — Pedestrian/Bicycle Bullet Railing Details
- Index 515-051 — Bridge Pedestrian/Bicycle Railing (Steel)
- Index 515-061 — Bridge Pedestrian/Bicycle Railing ( Aluminum )
- Index 515-062 — Pedestrian/Bicycle Railing (Aluminum)
- Index 515-070 — Aluminum Pipe Guiderail
- Index 515-080 — Steel Pipe Guiderail
- Index 520-001 — Curb and Gutter
Try it yourself — open your plan set in PDFDepth
Review, measure, and check plan sets against the standards they cite — free for 14 days.
Start for FreeText extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.