FDOT Standard Plans Index 522-003: Concrete Flared Driveways
Short answer
Index 522-003 is the FDOT Standard Plan for Concrete Flared Driveways, part of Series 522 (Incidental Construction). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.
Design Criteria
Design Criteria FDOT Design Manual (FDM) , FDM 214.
Design Assumptions and Limitations
Design Assumptions and Limitations Concrete Flared Driveways (previously known as: Flared Turnouts) are intended for curbed roadways designated as Connection Categories A and B. Refer to the design criteria in FDM 214 and FDM 222 for usage and design requirements. Based on the driveway categories, detectable warnings are typically not used in conjunction with Concrete Flared Driveways and should not be called for in the Plans.
Alpha-Numeric Identifications (e.g., G-1, M-1, & A-1) have been provided in Index 522- 003 for various standard driveway profiles to facilitate ease of callouts in the Plans. These identifications are classified based on right-of-way constraints (i.e., General, Marginal, and Adverse). Apply the options in accordance with the definitions in FDM 214 .
Payment
Payment Item number Item Description Unit Measure 522-2 Concrete Sidewalk and Driveways, 6” Thick SY See the BOE and Specification 522 for additional information on payment, pay item use and compensation.
What your plans must show
Plan Content Requirements for this index — the SPI's checklist for designers.
- Summary Boxes: Summarize quantities in the Summary of Sidewalk and Detectable Warnings or the Summary of Permanent Driveways , see BOE , Chapter
- 8. Detail the sidewalk and driveway layout in the Roadway Plan Views (i.e., show the intended sidewalk transition) and include the following callouts:
- 2. Side (either Left, Right or Median)
- 3. Driveway Profile Alpha-Numeric Identification Provide grade information on the Roadway Cross Sections or on Driveway Profiles at locations where additional grading is required beyond the back of sidewalk (i.e. Grade of Driveway , G D shown on Index 522-003 ) or if non-standard driveways are needed.
How PDFDepth uses this index
When a plan set cites Index 522-003, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.
Related indexes in Series 522
- Index 522-001 — Concrete Sidewalk
- Index 522-002 — Detectable Warnings and Sidewalk Curb Ramps
- Index 524-001 — Ditch Pavement and Sodding
- Index 534-200 — Precast Noise Walls
- Index 534-250 — Perimeter Wall
- Index 536-001 — Guardrail
- Index 536-002 — Guardrail Transitions and Connections for Existing Bridges
- Index 544-001 — Crash Cushion Details
Try it yourself — open your plan set in PDFDepth
Review, measure, and check plan sets against the standards they cite — free for 14 days.
Start for FreeText extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.