Skip to content

FDOT Standard Plans · FY 2026-27 · Series 635: Traffic Control Signals and Devices

FDOT Standard Plans Index 635-005: Fiber Optic Splice Vault

Short answer

Index 635-005 is the FDOT Standard Plan for Fiber Optic Splice Vault, part of Series 635 (Traffic Control Signals and Devices). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.

Design Criteria

Design Criteria AASHTO Standard Specification for Highway Bridges and AASHTO LRFD Bridge Design Specifications

Design Assumptions and Limitations

Design Assumptions and Limitations Index 635-005 provides requirements for installation of partially buried Fiber Optic Splice Vaults on medians or roadsides. See Specification 635 for additional information. This Index is primarily intended for use on Florida’s Turnpike Enterprise corridors, but it may also be used for other District corridors at the District’s discretion.

To accommodate different usage locations, change the Manhole Cover wording per the Plans Content Requirements below. With consideration for mowing and maintenance vehicles, Index 635-005 is designed for AASHTO H-20 loadings. At the discretion of the Engineer of Record, project-specific splice vaults may be used as an alternative to Index 635-005 .

These structural designs must be signed and sealed by a Professional Engineer licensed in the State of Florida.

Payment

Payment Item number Item Description Unit Measure 635-4-AB Fiber Optic Splice Vault EA See the BOE and Specification 635 for additional information on payment, pay item use and compensation.

What your plans must show

Plan Content Requirements for this index — the SPI's checklist for designers.

  • Call out the Fiber Optic Splice Vaults where needed in contract plans set. Visually, show these vaults to scale, and define the corner point locations as needed to establish the orientation in the plan view. The default lettering on the manhole cover top is, “TPK FIBER OPTIC”. To change this wording, place a project-specific call-out in the Plans (e.g., Manhole Custom Wording: “FDOT DISTRICT 5” ). For more information, see Index 635-005 , Note 2.
vaultbarssplicecenteredreqdhooksmanholeblockoutgroundfiberopticenclosures

How PDFDepth uses this index

When a plan set cites Index 635-005, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.

Related indexes in Series 635

All FDOT Standard Plans indexes

Try it yourself — open your plan set in PDFDepth

Review, measure, and check plan sets against the standards they cite — free for 14 days.

Start for Free

Text extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.