FDOT Standard Plans Index 649-010: Steel Strain Pole

Short answer

Index 649-010 is the FDOT Standard Plan for Steel Strain Pole, part of Series 649 (Traffic Control Signals and Devices). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.

Design Criteria

Design Criteria AASHTO LRFD Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals (LRFDLTS-1) ; Structures Manual (SM) , Volume 3, FDOT Modifications to LRFDLTS-1; Structures Manual (SM) Introduction, I.6

Design Assumptions and Limitations

Design Assumptions and Limitations See FDM 261 and Structures Manual (SM) , Volume 3 for additional design criteria. Use Index 649-010 in conjunction with the following design programs available for use on the Structures Design Office Website : • FDOT Strain Pole Program • University of Florida Bridge Software Institute ATLAS Program Foundation designs are based on the following conservative soil criteria which cover the great majority of soil types found in Florida: Classification = Cohesionless (Fine Sand) Friction Angle = 30 degrees Unit Weight = 50 pcf (assumed submerged) When the designer considers soil types at the specific site location to be of lesser strength properties than shown above, an analysis is required. Auger borings, SPT borings, or CPT soundings may be used as needed to verify the assumed soil properties, and at sites confirmed to be uniform, a single boring or sounding may cover several foundations.

Borings in the area that were performed for other purposes may be used to confirm the assumed soil properties. Determine maximum loads placed on poles and select the required pole type meeting the requirements of: Factored Flexural Resistance (M r ) = Φ M n , Where M r > M u Factored Flexural Resistance at Pole Bottom (kip*ft): Pole Type PS-IV PS-V PS-VI PS-VII PS-VIII PS-IX PS-X M r 160 270 340 450 540 620 730 Index 649-010 Steel Strain Pole

Payment

Payment Item number Item Description Unit Measure 649-1-ABC Steel Strain Pole EA See the BOE and Specification 649 for additional information on payment, pay item use and compensation.

What your plans must show

Plan Content Requirements for this index — the SPI's checklist for designers.

  • Roadway Plans: Complete the " Strain Pole Schedule " provided with the FDOT CAD Bar Menu, Linked Data Manager, and include in the Roadway Plans. Signalization Plans: See the FDM 941 . Summarize poles in “ Tabulation of Quantities” .
astmpolegradewireboltssteelwashersplatenutsbasehandholeanchor

How PDFDepth uses this index

When a plan set cites Index 649-010, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.

Related indexes in Series 649

All FDOT Standard Plans indexes

Try it yourself — open your plan set in PDFDepth

Review, measure, and check plan sets against the standards they cite — free for 14 days.

Start for Free

Text extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.