FDOT Standard Plans Index 654-001: Rectangular Rapid Flashing Beacon Assembly
Short answer
Index 654-001 is the FDOT Standard Plan for Rectangular Rapid Flashing Beacon Assembly, part of Series 654 (Traffic Control Signals and Devices). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.
Design Criteria
Design Criteria FDOT Traffic Engineering Manual (TEM) ; Manual on Uniform Traffic Control Devices (MUTCD); FDOT Design Manual (FDM); AASHTO LRFD Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals (LRFDLTS-1); Structures Manual (SM), Volume 3; FDOT Modifications to LRFDLTS-1; Structures Manual (SM) Introduction, I.6
Design Assumptions and Limitations
Design Assumptions and Limitations Allowable Uses a. An RRFB shall only be installed to function as a pedestrian-actuated conspicuity enhancement. b.
An RRFB shall only be used to supplement a post-mounted W11-2 (Pedestrian), S1-1 (School), or W11-15 (Trail) crossing warning sign with a diagonal downward arrow (W16-7P) plaque, or an overhead-mounted W11-2, S1-1, or W11-15 crossing warning sign, located at or immediately adjacent to an uncontrolled marked crosswalk. c. Except for crosswalks across the approach to or egress from a roundabout, an RRFB shall not be used for crosswalks across approaches controlled by YIELD signs, STOP signs, traffic control signals, or pedestrian hybrid beacons.
d. In the event sight distance approaching the crosswalk at which RRFBs are used is less than deemed necessary by the engineer, an additional RRFB may be installed on that approach in advance of the crosswalk, as a pedestrian-actuated conspicuity enhancement to supplement a W11-2 (Pedestrian), S1-1 (School), or W11-15 (Trail) crossing warning sign with an AHEAD (W16-9P) or distance (W16-2P or W16-2aP) plaque. If an additional RRFB is installed on the approach in advance of the crosswalk, it shall be supplemental to and not a replacement for the RRFBs at the crosswalk itself.
Sign/Beacon Assembly Locations a. For any approach on which RRFBs are used to supplement post-mounted signs, at least two W11-2, S1-1, or W11-15 crossing warning signs (each with an RRFB unit and a W16-7P plaque) shall be installed at the crosswalk, one on the right- hand side of the roadway and one on the left-hand side of the roadway. On a divided highway, the left-hand side assembly should be installed on the median, if practical, rather than on the far left-hand side of the highway.
b. An RRFB shall not be installed independent of the crossing warning signs for the approach that the RRFB faces. If the RRFB unit is supplementing a post- mounted sign, the RRFB unit shall be installed on the same support as the associated W11-2, S1-1, or W11-15 crossing warning sign and plaque.
See FHWA MUTCD Chapter 4 . Index 654 - 001 Rectangular Rapid Flashing Beacon Assembly
Payment
Payment Item number Item Description Unit Measure 654-2-AB Rectangular Rapid Flashing Beacon Sign Assembly (RRFB) AS See the BOE and Specification 654 for additional information on payment, pay item use and compensation.
What your plans must show
Plan Content Requirements for this index — the SPI's checklist for designers.
- In the Signalization Plans: Show, detail, and tabulate RRFBs mounted overhead or as a standalone assembly in accordance with FDM 941 .
How PDFDepth uses this index
When a plan set cites Index 654-001, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.
Related indexes in Series 654
- Index 659-010 — Span Wire Mounted Sign Details
- Index 659-020 — Camera Mounting Details
- Index 660-001 — Vehicle Loop Installation
- Index 665-001 — Pedestrian Detector Assembly Installation Details
- Index 671-001 — Standard Signal Operating Plans
- Index 676-010 — Cabinet Installation Details
- Index 695-001 — Traffic Monitoring Site
- Index 700-010 — Single Column Ground Signs
Try it yourself — open your plan set in PDFDepth
Review, measure, and check plan sets against the standards they cite — free for 14 days.
Start for FreeText extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.