FDOT Standard Plans · FY 2026-27 · Series 550: Incidental Construction
FDOT Standard Plans Index 550-010: Bridge Fencing (Vertical)
Short answer
Index 550-010 is the FDOT Standard Plan for Bridge Fencing (Vertical), part of Series 550 (Incidental Construction). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.
Design Criteria
Design Criteria NCHRP Report 350 , Test Level 3 Criteria; AASHTO LRFD Bridge Design Specifications ; Structures Design Guidelines ( SDG )
Design Assumptions and Limitations
Design Assumptions and Limitations The Traffic Railing mounted version of this fence (back of railing mounted with tension wires) is based on a design that was successfully crash tested in accordance with the AASHTO Guide Specifications for Bridge Railings Performance Level 2 pickup test. Modifications have been made to improve the crashworthiness to NCHRP Report 350 Test Level 3 Criteria. This fence can be used on Index 521 - 422, 521 - 423, 521 - 42 7, 521 - 428 and 521 - 480 Series Traffic Railings, certain non - FDOT standard concrete traffic railing s meeting the requirements of SDG 6.7 and on existing New Jersey and F - Shape Traffic Railings listed in the Standard Plan s Instructions Index 536 - 0 02.
The Concrete Parapet mounted version of this fence (top of parapet mounted with horizontal rails) is not a crash tested design and cannot be used on traffic railings. This fence can be used on Concrete Parapets constructed in accordance with Index 521 - 820 in lieu of the bullet railing shown on Indexes 521 - 820 and 515 - 0 22. Evaluate the expansion joint movements of the bridge.
Expansion rails are required for concrete parapet installations at expansion joints where the total movement exceeds 1 - inch. If the total movement at an individual expansion joint is 6 - inches or less, the bridge fence will span the joint without using an expansion assembly. If the total movement at an individual expansion joint exceeds 6 - inches, an Expansion Assembly mus t be installed at that location.
Use of the Concrete Parapet mounted version of this fence in lieu of Index 550 - 0 11 Bridge Fencing (Curved Top) Index 550 - 0 12 Bridge Fencing (Enclosed) , or Index 550 - 0 13 Bridge Fencing (Over Railroad) should be based on project and site specific requirements.
General Notes
General Notes, e.g., zinc or aluminum coated, or polyvinyl chloride (PVC) coated. If PVC coated fence is used, include the following notes in the General Notes: 1. A note specifying the color of the PVC coating for chain link fabric.
2. A note to paint the fence framework to match the color of the PVC chain link fabric. 3.
A note for preparation of galvanized steel for painting. 4. A note to coat tension wire and fence fittings to match the color of the PVC chain link fabric.
Consideration for Approval of Alternative Technical Proposals Alternate fencing systems may be considered for approval with concurrence from the District Structures Design Engineer. Fabricators must be listed in the Material Acceptance and Certification System (MAC) as an approved Metals Production Facility. Design calculations meeting the wind load requirements for the project site in accordance with the SDG must be submitted for review and approval by the EOR.
Technical Specifications with material and testing requirements should be submitted by the Contractor for approval prior to acceptance of any alternative technical proposal ( Contractor Savings Initiative for Design - Bid - Build projects, or Alternative Technical Concept for Design Build/P3 projects).
Payment
Payment Item number Item Description Unit Measure 550 - 10 - 315 Fencing, Type R, 0 - 5.0', Vertical LF 550 - 10 - 325 Fencing, Type R, 5.1 - 6.0', Vertical LF 550 - 10 - 335 Fencing, Type R, 6.1 - 7.0', Vertical LF
What your plans must show
Plan Content Requirements for this index — the SPI's checklist for designers.
- In the Structures and/or Roadway Plans: Show and label, by name or Index number, the Bridge Fencing (Vertical) on the Plan and Elevation, Typical Section, Superstructure and Approach Slab sheets, Retaining Wall Control Drawings, and other sheets as required. Show the limits of fencing in the plans if they are not from begin of approach slab at Begin Bridge to end of approach slab at End Bridge. Show quantities for bridge fencing with quantities for Traffic Railings and/or Concrete Parapets. See FDM 902 for guidance on Estimated Quantities Report.
- Standard Plan s Instructions Topic No. 625
- - 010 Bridge Fencing (Vertical) Determine if bridge fencing requires grounding. If required, provide details in the superstructure sheets. Provide locations for expansion joints requiring expansion rails or expansion assemblies in the superstructure layout sheets. Designate the required finish in the
How PDFDepth uses this index
When a plan set cites Index 550-010, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.
Related indexes in Series 550
- Index 550-001 — Fence Type a
- Index 550-002 — Fence Type B
- Index 550-003 — Cantilever Slide Gate Type B Fence
- Index 550-004 — Fence Location
- Index 550-011 — Bridge Fencing On Parapet (Curved Top)
- Index 550-012 — Bridge Fencing ( Enclosed )
- Index 550-013 — Bridge Fencing On Barrier (Curved Top)
- Index 570-001 — Permanent Erosion Control
Try it yourself — open your plan set in PDFDepth
Review, measure, and check plan sets against the standards they cite — free for 14 days.
Start for FreeText extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.