Skip to content

FDOT Standard Plans · FY 2026-27 · Series 715: Signing, Pavement Markings and Lighting

FDOT Standard Plans Index 715-003: Utility Conflict Pole

Short answer

Index 715-003 is the FDOT Standard Plan for Utility Conflict Pole, part of Series 715 (Signing, Pavement Markings and Lighting). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.

Design Criteria

Design Criteria AASHTO LRFD Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals (LRFDLTS-1) ; Structures Manual (SM) , Volume 3, FDOT Modifications to LRFDLTS-1; Structures Manual (SM) Introduction, I.6

Design Assumptions and Limitations

Design Assumptions and Limitations See notes on Indexes 715-001 & 002 , FDM 231 , FDM 261 , and Structures Manual (SM) , Volume 3. Fixture Mounting Height is defined in the Lighting Design Requirements. The design weight of luminaire is 75 lbs, and the equivalent projected area (EPA) of the luminaire is 1.55 square feet.

Foundations are based upon the following conservative soil criteria (which covers the majority of soil types found in Florida) Classification = Cohesionless (Fine Sand) Friction Angle = 30 degrees Unit Weight = 50 pcf (Submerged) Bearing Resistance = 2000 psf Only in cases where the Designer considers the soil types at the specific site to be of lesser strength properties should an analysis be required. Auger borings, SPT borings or CPT soundings may be utilized as needed to verify the assumed soil properties, and at relatively uniform sites, a single boring or sounding may cover several foundations. Borings in the area that were performed for other purposes may be used to confirm the assumed soil properties.

Unique site circumstances where poorer soil conditions are encountered may require custom foundation designs. Standard Roadway Aluminum Light Poles and Utility Conflict Poles: Design Mounting Height is the height measured from the top of the foundation to the light fixture. Fill Height is the height measured from the natural ground line adjacent to the poles to the finish grade at the pole base.

The Fill Height above surrounding terrain may be limited to 25 feet. Wind Height is measured from the natural ground elevation adjacent to the poles, to the light fixture; therefore, the Wind Height at Fixture is equal to the Design Mounting Height plus the Fill Height , rounded up to the next highest 5-foot increment. Indexes 715-001, 715-002, & 715-003 Conventional Lighting Design Mounting Heights in the Standard Plans are the following: • Standard Aluminum Lighting, Conventional or Wildlife Sensitive: 30, 35, 40, 45, or 50-foot height with either a top-mounted fixture or a single arm fixture (arm lengths of 8, 10, 12 or 15 feet).

• Standard Aluminum Lighting, Wildlife-Sensitive Only: 20 or 25-foot height with single arm fixture (arm lengths of 8 or 10 feet) • Utility Conflict Pole: 35, 40, 45, or 50-foot height with single arm fixture (arm length of 16 feet) Locate poles in accordance with FDM 231 for Lighting along with FDM 215 for Roadside Safety and FDM 222 for Pedestrian Facilities. Placement of standalone light poles is not permitted in medians. However, for placement near frontage roads or other constrained conditions requiring project-specific approval, the Minimum Falling Area applies.

Where a pole with a frangible base is placed between adjacent traffic lanes, a Minimum Falling Area is required on both sides. This falling area is an offset measured laterally from the roadway, between the edge of traveled way and the pole face, and it must be a distance of at least 40% of the Mounting Height. These poles are designed for ground mounts per the Standard Plans details.

Mounting on top of walls or bridge decks is not permitted. Poles may be placed on pedestals using project-specific mounting designs following the requirements of Index 521-650 and 521-660. Median Barrier/Traffic Railing Mounted Aluminum Light Poles: Median Traffic Railing Mounted lighting should not be used on bridges unless the light level requirement of FDM 231 cannot be meet be by installing the lighting on the outside of the bridge traffic railing using Index 521-660 .

Design Mounting Height is the distance from finished grade at the pole base to the light fixture. Base Height is the height measured from the natural ground line adjacent to the poles or the mean high water to the finished grade at the pole base. …

Payment

Payment Item number Item Description Unit Measure 715-4-AB Light Pole, Complete EA See the BOE and Specification 715 for additional information on payment, pay item use and compensation.

polebaseastmalloysteelgradeshoetransformerluminairefoundationboltsnuts

How PDFDepth uses this index

When a plan set cites Index 715-003, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.

Related indexes in Series 715

All FDOT Standard Plans indexes

Try it yourself — open your plan set in PDFDepth

Review, measure, and check plan sets against the standards they cite — free for 14 days.

Start for Free

Text extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.