FDOT Standard Plans · FY 2026-27 · Series 715: Signing, Pavement Markings and Lighting
FDOT Standard Plans Index 715-240: Maintenance Lighting f or Box Girders
Short answer
Index 715-240 is the FDOT Standard Plan for Maintenance Lighting f or Box Girders, part of Series 715 (Signing, Pavement Markings and Lighting). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.
Design Criteria
Design Criteria NFPA National Electric Code ; Structures Design Guidelines ( SDG )
Design Assumptions and Limitations
Design Assumptions and Limitations This standard shows basic details and requirements for maintenance lighting systems located inside concrete and steel box girder superstructures. It does not show all structural elements and is not intended to show the exact location of conduit runs. Lighting fixtures and equipment locations must be coordinated with the box girder superstructure details, e.g., structural steel components, metal stay - in - place deck formwork and post tensioning systems in concrete box girders.
This standard may be used in conjunction with Index 630 - 010 .
Payment
Payment Item number Item Description Unit Measure 715 - 50 Lighting - Inside Box Girder L S
What your plans must show
Plan Content Requirements for this index — the SPI's checklist for designers.
- In the Structures Plans: See SDG 4.6, 4.8 and 5.6 for location requirements of electrical components. Prepare supplemental designs as required showing locations and details of conduit runs, power sources and other electrical components and incidental items.
How PDFDepth uses this index
When a plan set cites Index 715-240, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.
Related indexes in Series 715
- Index 715-001 — Conventional Lighting
- Index 715-002 — Standard Aluminum Lighting
- Index 715-003 — Utility Conflict Pole
- Index 715-010 — High Mast Lighting
- Index 000-510 — Superelevation Transitions - High Speed Roadways
- Index 000-511 — Superelevation Transitions - Low Speed Highways
- Index 000-525 — Ramp Terminals
- Index 102-100 — Series - Temporary Barrier
Try it yourself — open your plan set in PDFDepth
Review, measure, and check plan sets against the standards they cite — free for 14 days.
Start for FreeText extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.