FDOT Standard Plans Index 715-010: High Mast Lighting
Short answer
Index 715-010 is the FDOT Standard Plan for High Mast Lighting, part of Series 715 (Signing, Pavement Markings and Lighting). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.
Design Criteria
Design Criteria AASHTO LRFD Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals (LRFDLTS-1) ; Structures Manual (SM) , Volume 3, FDOT Modifications to LRFDLTS-1; Structures Manual (SM) Introduction, I.6
Design Assumptions and Limitations
Design Assumptions and Limitations See notes on Index 715-010 , FDM 231 , FDM 261 , and Structures Manual (SM) , Volume 3. Design wind pressure is based on a maximum fill height of 25 feet. Poles are designed for up to a 6 mil galvanization thickness.
Foundations are based upon the following conservative soil criteria (which covers the majority of soil types found in Florida) Classification = Cohesionless (Fine Sand) Friction Angle = 30 degrees Unit Weight = 50 pcf (Submerged) Only in cases where the Designer considers the soil types at the specific site location to be of lesser strength properties should an analysis be required. Auger borings, SPT borings or CPT soundings may be utilized as needed to verify the assumed soil properties, and at relatively uniform sites, a single boring or sounding may cover several foundations. Furthermore, borings in the area that were performed for other purposes may be used to confirm the assumed soil properties.
Use Index 715-010 in conjunction with the High Mast-LRFD Mathcad 15 computer program located on the Structures Design Programs Library website.
Payment
Payment Item number Item Description Unit Measure 715-19-AB High Mast Light Pole, Complete EA See the BOE and Specification 715 for additional information on payment, pay item use and compensation.
How PDFDepth uses this index
When a plan set cites Index 715-010, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.
Related indexes in Series 715
- Index 715-001 — Conventional Lighting
- Index 715-002 — Standard Aluminum Lighting
- Index 715-003 — Utility Conflict Pole
- Index 715-240 — Maintenance Lighting f or Box Girders
- Index 000-510 — Superelevation Transitions - High Speed Roadways
- Index 000-511 — Superelevation Transitions - Low Speed Highways
- Index 000-525 — Ramp Terminals
- Index 102-100 — Series - Temporary Barrier