FDOT Standard Plans Index 471-030: Fender Systems - Prestressed Concrete Piles & FRP Wales

Short answer

Index 471-030 is the FDOT Standard Plan for Fender Systems - Prestressed Concrete Piles & FRP Wales, part of Series 471 (Structures). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.

Design Criteria

Design Criteria Structures Design Guidelines ( SDG ) 3.14

Design Assumptions and Limitations

Design Assumptions and Limitations Do not use this fender system unless approved by the District for use on the specific project. Standard Plan s Index 471 - 0 30 includes a fully designed Fender System with 14" square prestressed concrete piling having a maximum "Energy Capacity" of 50 ft - kip ” . Refer to SDG 3.14 for additional Fender System design criteria, assumptions and limitations.

Use this standard with Index 510 - 001 .

Materials

Materials Table" and one "Fender System Table of Variables" are required for each Fender System location within a project. For projects with multiple fender systems or configurations, clearly note which Fender System the Tables are applicable to. See FDM 115 for more information regarding use of Data Tables.

Base the Minimum Pile Tip Elevations on the minimum embedment of 20 feet for the 14" square prestressed concrete piles into soil having a blow count (N) greater than 6. Standard Plan s Instructions Topic No. 625 - 010 - 003 Index 471 - 030 Fender Systems - Prestressed Concrete Piles & FRP Wales Provide the required Clearance Gauge details in the plans adjacent to the Data Tables.

Specify the numeral height, sign dimensions, foot marks and intermediate foot marks (when required), based on coordination with the USCG District Commander, 33 CFR 118.160 and the USCG Bridge Lighting and Other Signals Manual . Standard Plan s Instructions Topic No. 625 - 010 - 003 Index 471 - 030 Fender Systems - Prestressed Concrete Piles & FRP Wales Table for use with Index 471 - 0 30 Fender Systems - Prestressed Concrete Piles: Standard Plan s Instructions Topic No.

625 - 010 - 003 Index 471 - 030 Fender Systems - Prestressed Concrete Piles & FRP Wales T able for use with a Drilled Shaft Foundation: Standard Plan s Instructions Topic No. 625 - 010 - 003 Index 471 - 030 Fender Systems - Prestressed Concrete Piles & FRP Wales

Payment

Payment Include quantity for Composite Marine Lumber 10" X 10" Wales Mark A under Pay Item for Plastic Marine Lumber (Reinforced). Include quantity for all other Plastic Lumber under Pay Item for Plastic Marine Lumber (Non - Reinforced). In AASHTOWare Project Preconstruction TM (formerly TRNS*PORT ) , include estimated quantities for the Index 471 - 0 30 fender systems.

Item number Item Description Unit Measure 471 - 1 - 1 Fender System, Plastic Marine Lumber, Reinforced MB 471 - 1 - 2 Fender System, Plastic Marine Lumber, Non - Reinforced MB 455 - 34 - 2 Prestressed Concrete Piling, 14" Sq. LF

What your plans must show

Plan Content Requirements for this index — the SPI's checklist for designers.

  • In the Structures Plans: Include Index 471
  • - 0 30 on waterways where a fender system is required and no barge traffic is present Prepare and include in the plans supplemental project specific designs and details for the following items:
  • • Electrical service for navigation lights including conduit path from bridge to fender system and identification of service point. Coordinate design with Index 510
  • - 001 and Specifications Section
  • • Access ladders and catwalks from bridge to fender system are optional and may be included at the discretion of the District. Designate in the plans the type of decking material to be used for catwalks: 2" x 12" Plastic Lumber or Fiberglass Open Grating. Catwalk decking material shall be determined by the District. Complete the following "Data Tables" and include them in the plans. One "Estimated Bill of
accordanceprovidestainlesssteelnutslumberfurnishboltsfiberglassopengratingwales

How PDFDepth uses this index

When a plan set cites Index 471-030, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.

Related indexes in Series 471

All FDOT Standard Plans indexes

Try it yourself — open your plan set in PDFDepth

Review, measure, and check plan sets against the standards they cite — free for 14 days.

Start for Free

Text extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.