FDOT Standard Plans Index 700-011: Single Column Cantilever Ground Mounted Sign

Short answer

Index 700-011 is the FDOT Standard Plan for Single Column Cantilever Ground Mounted Sign, part of Series 700 (Signing, Pavement Markings and Lighting). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.

Design Criteria

Design Criteria AASHTO LRFD Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals (LRFDLTS-1) ; Structures Manual (SM) , Volume 3, FDOT Modifications to LRFDLTS-1; Structures Manual (SM) Introduction, I.6

Design Assumptions and Limitations

Design Assumptions and Limitations Index 700-011 may not be used as a substitute for Index 700-020 . Only use Index 700-011 on curb & gutter facilities where the distance between the curb and the sidewalk restricts the use of Index 700-020 . If Index 700-011 is used, significant sign flutter should be expected during wind events.

The sign location should be checked to insure sufficient area exists behind the sidewalk for the column. Work with Index 700- 010 . See notes on Index 700-011 , FDM 230 , FDM 261 , and the Structures Manual (SM) , Volume 3.

Design Wind Speed is 110 MPH. Foundation designs are based on the following conservative soil criteria which cover the majority of soil types found in Florida: Classification = Cohesionless (Fine Sand) Friction Angle = 30 degrees Unit Weight = 50 pcf (assumed submerged)

Payment

Payment Item number Item Description Unit Measure 700-1-9BB Single Column Sign (F&I, Cantilever Ground Mount) EA See the BOE and Specification 700 for additional information on payment, pay item use and compensation.

What your plans must show

Plan Content Requirements for this index — the SPI's checklist for designers.

  • See the FDM 940 .
boltbasecolumnsigntablesleeveplatewindbeamaluminumsizestub

How PDFDepth uses this index

When a plan set cites Index 700-011, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.

Related indexes in Series 700

All FDOT Standard Plans indexes

Try it yourself — open your plan set in PDFDepth

Review, measure, and check plan sets against the standards they cite — free for 14 days.

Start for Free

Text extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.