Skip to content

FDOT Standard Plans · FY 2026-27 · Series 700: Signing, Pavement Markings and Lighting

FDOT Standard Plans Index 700-012: Single Post Sign Support Barrier Side-Mounted

Short answer

Index 700-012 is the FDOT Standard Plan for Single Post Sign Support Barrier Side-Mounted, part of Series 700 (Signing, Pavement Markings and Lighting). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.

Design Criteria

Design Criteria AASHTO LRFD Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals (LRFDLTS-1) ; Structures Manual (SM) Volume 3, FDOT Modifications to LRFDLTS-1; Structures Manual (SM) Introduction, I.6

References

References; Structures Design Guidelines (SDG) ; FDOT Design Manual (FDM)

Design Assumptions and Limitations

Design Assumptions and Limitations See notes on Index 700-012 , FDM 230 , FDM 261 , and the Structures Manual (SM) , Volume 3. Work with Index 700-010 . Limit the use of Index 700-012 to Bridge Traffic Railings and Wall Coping with Concrete Barriers where ground mounting is not feasible and signing cannot be placed outside the limits of the traffic railing.

Intended for use with static signs only. Tabulated Maximum Sign Area, Dim A and Dim C, are based on a Wind Speed of 110 MPH and a bridge height of 75' above surrounding areas. Sign Post clearance from front face of barrier is detailed to meet the maximum setback distance requirements of SDG 6.7 .

Maximum sign width is 60 inches. Sign Supports have been detailed for placement on new or existing concrete traffic and pedestrian railings. Anchorage details are for Adhesive Bonded Anchors.

Undercut Anchors may be used in lieu of Adhesive bonded Anchors when approved by the District Structures Design Engineer and the State Structures Engineer, on a project-by-project basis. If approved, project specific details will be required in the Plans. When using Undercut Anchors, the designer must submit a request to the District Specifications Office to use Developmental Specifications Dev416 and Dev937 for Post-installed Anchor Systems which includes provisions for both Adhesive Bonded Anchors and Undercut Anchors.

See SDG 1.6 for more information.

Payment

Payment Item number Item Description Unit Measure 700-1-3BB Single Column Sign (F&I, Barrier Side Mount) EA 102-62-12 Barrier Mounted Work Zone Sign (Index 102-012) ED See the BOE and Specification 700 for additional information on payment, pay item use and compensation.

What your plans must show

Plan Content Requirements for this index — the SPI's checklist for designers.

  • - 012 Single Post Sign Support Barrier Side
signplatepostsupportgeneraltrafficastmnutsrailingwasherbasebridge

How PDFDepth uses this index

When a plan set cites Index 700-012, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.

Related indexes in Series 700

All FDOT Standard Plans indexes

Try it yourself — open your plan set in PDFDepth

Review, measure, and check plan sets against the standards they cite — free for 14 days.

Start for Free

Text extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.