FDOT Standard Plans Index 700-013: Single Post Sign Support Barrier Top-Mounted
Short answer
Index 700-013 is the FDOT Standard Plan for Single Post Sign Support Barrier Top-Mounted, part of Series 700 (Signing, Pavement Markings and Lighting). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.
Design Criteria
Design Criteria AASHTO LRFD Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals (LRFDLTS-1) ; Structures Manual (SM) , Volume 3, FDOT Modifications to LRFDLTS-1; Structures Manual (SM) Introduction, I.6
References
References; Structures Design Guidelines (SDG) ; FDOT Design Manual (FDM)
Design Assumptions and Limitations
Design Assumptions and Limitations See notes on Index 700-013 , FDM 215 , FDM 230 , FDM 261 , and the Structures Manual (SM) , Volume 3. Work with Index 700-010 . Do not use Index 700-013 for mounting permanent signs to shoulder traffic railings or concrete barriers unless there is insufficient room to accommodate the use of Indexes 700-010 or 700-012 .
Intended for use with static signs only. For permanent signs, tabulated maximum sign areas and corresponding post diameters are based on a wind speed of 110 mph installed on barriers less than 30 feet above surrounding areas. Base plates Type A and B are sized for permanent installations and designed for a wind speed of up to 110 mph when installed on existing FDOT Standard concrete traffic railings/barriers with 1" diameter anchor bolts.
Temporary sign post and plate (Base Plate Type C) designs are based on a wind speed of 80 mph with a maximum 24 square foot sign. These sign structures are designed for temporary placement on all standard FDOT barriers, including installations on temporary concrete barriers covered by Index 102-100 . Anchorage details are for Adhesive Bonded Anchors.
Undercut Anchors may be used in lieu of Adhesive Bonded Anchors when approved by the District Structures Design Engineer and the State Structures Engineer, on a project-by-project basis. If approved, project specific details will be required in the plans. When using Undercut Anchors, the designer must submit a request to the District Specifications Office to use Developmental Specifications Dev416 and Dev937 for Post-installed Anchor Systems which includes provisions for both Adhesive Bonded Anchors and Undercut Anchors.
See the SDG 1.6 for more information.
Payment
Payment Item number Item Description Unit Measure 700-1-2BB Single Column Sign (F&I, Barrier Top-Mount) EA 102-62-13 Barrier Mounted Work Zone Sign (Index 102-013) ED See the BOE and Specification 700 for additional information on payment, pay item use and compensation.
What your plans must show
Plan Content Requirements for this index — the SPI's checklist for designers.
- For Permanent Signs: See the FDM 940 . For all Temporary/Work Zone Signs: Use Index 102-600 to layout sign locations in the Plans. Index 102-600 requires signs to be post mounted. When post mounted criteria cannot be met, use Index 700-013 , show the location of the barrier mounted signs in the Plans, and include the pay item for barrier mounted work zone signs. However, to reduce the amount of barrier mounted work zone signs, increase the sign spacing as allowed by Index 102-600 . Index 700
- - 013 Single Post Median Barrier Mounted Sign Support
How PDFDepth uses this index
When a plan set cites Index 700-013, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.
Related indexes in Series 700
- Index 700-010 — Single Column Ground Signs
- Index 700-011 — Single Column Cantilever Ground Mounted Sign
- Index 700-012 — Single Post Sign Support Barrier Side-Mounted
- Index 700-020 — Multi-Column Ground Sign
- Index 700-030 — Wind and Hanger Beams for Overhead Signs
- Index 700-031 — External Lighting for Signs
- Index 700-040 — Cantilever Sign Structure
- Index 700-041 — Span Sign Structure
Try it yourself — open your plan set in PDFDepth
Review, measure, and check plan sets against the standards they cite — free for 14 days.
Start for FreeText extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.