Skip to content

FDOT Standard Plans · FY 2026-27 · Series 700: Signing, Pavement Markings and Lighting

FDOT Standard Plans Index 700-020: Multi-Column Ground Sign

Short answer

Index 700-020 is the FDOT Standard Plan for Multi-Column Ground Sign, part of Series 700 (Signing, Pavement Markings and Lighting). The sections below are extracted from FDOT's Standard Plans Instructions (SPI) for this index — design criteria, assumptions and limitations, and what your plans must show.

Design Criteria

Design Criteria AASHTO LRFD Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals (LRFDLTS-1) ; Structures Manual (SM) , Volume 3 , FDOT Modifications to LRFDLTS-1 ; Structures Manual (SM) Introduction, I.6

Design Assumptions and Limitations

Design Assumptions and Limitations See notes on Index 700-020 and Structures Manual (SM) , Volume 3. The breakaway capabilities of a multi-column ground sign are unidirectional (i.e., the fuse and hinge plate assembly is designed to activate from impacts in one direction). Systems with columns within a 7-foot span must use posts with a mass of 18 lb/ft or less.

Larger posts with masses up to 45 lb/ft may also be used but the columns must be more than 7 feet apart. The total mass of the sign assembly above the slip-plane and below the hinge must be less than or equal to 600 pounds. Foundation designs are based on the following conservative soil criteria which cover the majority of soil types found in Florida: Classification = Cohesionless (Fine Sand) Friction Angle = 30 degrees Unit Weight = 50 pcf (assumed submerged) Use Index 700-020 in conjunction with the Multi-Post Sign-LRFD v1.1 located on the Structures Design Programs Library website.

Payment

Payment Item number Item Description Unit Measure 700-2-BB Multi-Column Sign ES See the BOE and Specification 700 for additional information on payment, pay item use and compensation.

What your plans must show

Plan Content Requirements for this index — the SPI's checklist for designers.

  • Column size must be shown in the Plans. See the FDM 940 for additional information.
columnastmsignbasewasherfoundationwashersboltstablenutssteelalloy

How PDFDepth uses this index

When a plan set cites Index 700-020, PDFDepth's AI Plan Review cross-references the set against the Plan Content Requirements for the FDOT indexes it cites and flags items that appear to be missing — each with a citation to the sheet. A human reviewer verifies every flag before it counts.

Related indexes in Series 700

All FDOT Standard Plans indexes

Try it yourself — open your plan set in PDFDepth

Review, measure, and check plan sets against the standards they cite — free for 14 days.

Start for Free

Text extracted from FDOT Standard Plans FY 2026-27, a public-domain Florida state publication. Always verify against the current edition at fdot.gov. PDFDepth is not affiliated with FDOT.